Ultrasonic Cleaner Solution for Dental Instruments: Enzymatic and Non-Enzymatic Compared
How enzymatic and non-enzymatic ultrasonic cleaner solution compare for dental instruments: soils, pH, dilution, cycle time and bath changes.

Enzymatic ultrasonic cleaner solution is designed for clinical instruments soiled with blood and tissue: protease enzymes break down protein soil, and multi-enzyme blends add amylase and lipase for starches and fats. Non-enzymatic general purpose solutions clean with detergents alone and suit mixed loads that also carry pumice, plaster or buffing compounds, while tartar, stain and cement removers treat prosthetics and appliances in a separate beaker.
Cavitation does the mechanical work: sound waves form microscopic bubbles that collapse against the instruments and loosen the debris. CDC places cleaning before every disinfection or sterilization step and names the ultrasonic cleaner among the automated methods that improve cleaning and reduce exposure to blood. Instrument cleaning is a separate step from surface disinfection with dental disinfectant wipes, and most ultrasonic solutions make no disinfection claim.
Instrument cleaning solutions for ultrasonic baths range from enzymatic and general purpose concentrates to tablets, single-dose packets and ready-to-use stain and cement removers.
What to Compare Between Ultrasonic Cleaner Solutions
Six characteristics separate one ultrasonic cleaner solution from another.
- Chemistry. Enzymes digest organic soil such as blood, while non-enzymatic formulas rely on detergents and alkaline salts.
- pH and materials. Enzymatic concentrates are mostly neutral, while some general purpose solutions are strongly alkaline and stain removers strongly acidic, so labels list the materials each one is safe on, such as aluminum, plastics and rubber.
- Dilution and yield. Most enzymatic concentrates take 1 oz per gallon of water, while general purpose concentrates range from that to much stronger mixes, which changes how many tank fills a bottle gives.
- Format. Liquid concentrates come in gallon, quart and metered-dose bottles, alongside powders, effervescent tablets and single-dose packets.
- Soil type. Blood and tissue respond to enzymes, laboratory soils to general purpose detergents, and set cement, tartar and stain to specialty removers.
- Additional claims. Some solutions double as presoaks, evacuation system cleaners or holding solutions, add corrosion inhibitors or carry an EPA registration as a germicide.
Enzymatic Ultrasonic Cleaner Solution for Blood and Tissue
Protease enzymes cut the proteins in dried blood, tissue and saliva into fragments that the detergent and the bubbles carry away. Dual-enzyme concentrates such as Enzymax combine two enzymes, and triple-enzyme ones such as Tri-Clean add enzymes for starches and fats as well as protein. Labels differ on water temperature, from room temperature to warm water, so the bath is filled as each label states.
For cassette-based processing, a dual-enzyme ultrasonic cleaner solution with a mineral-protecting agent handles daily instrument loads and doubles as an evacuation cleaner.
Daily instrument and cassette loads: Hu-Friedy Enzymax Dual Enzyme Ultrasonic Detergent and Presoak
Enzymax is a dual-enzyme liquid concentrate for ultrasonic cleaning and presoaking of dental instruments and cassettes. Its Steelgard agents protect instruments from the water minerals that cause buildup, spotting and corrosion, and it can also be used as an evacuation system cleaner. It dilutes at 1:128, or 1 oz per gallon, and the formula is biodegradable and phosphate-free. Best for: cassette-based instrument processing, daily mixed instrument loads, practices that clean evacuation lines with the same product.
Where soils include oils and starches as well as blood, a triple-enzyme concentrate with rust inhibitors covers the wider range.
Blood, starches and fats: Tri-Clean Triple Enzymatic Cleaner Concentrate
Tri-Clean is a concentrated enzymatic cleaner for ultrasonic and manual cleaning of dental and surgical instruments. Its blend of protease, amylase and lipase with a surfactant system removes protein, starches, oils and lipids, and the neutral pH, non-corrosive formula includes rust inhibitors for use on all metals. It dilutes at 1 oz per gallon of water. Best for: surgical and hygiene instruments with mixed organic soils, baths that need rust inhibitors, teams that dose by the ounce.
Do Enzymatic Solutions Clean Better Than Non-Enzymatic Ones?
In laboratory testing, enzymatic products removed organic soil better. Seneviratne et al. (2025) tested 13 commercial detergents on standard test indicators and on artificially soiled dental instruments, either soaking them or running them in an ultrasonic cleaner at different temperatures and times. Results varied widely between products, enzymatic products consistently did better than non-enzymatic ones, the ultrasonic cleaner did better than soaking, and results peaked after 10 minutes in water at 40 degrees C.
The test soil was not real patient debris, so the study ranks types of solution and conditions of use rather than the products listed here.
Cayo-Rojas et al. (2021) cleaned 192 used endodontic files either in an ultrasonic bath or by hand with a brush, with and without an enzymatic detergent. Both methods cleaned significantly better with the enzymatic detergent; without it the ultrasonic bath did better than brushing, and with it the two methods were similar. Cleanliness was judged by eye on one type of file, and the abstract does not say what the bath without enzymes contained, so the study shows the value of enzymes rather than comparing them with a non-enzymatic detergent.
Non-Enzymatic Ultrasonic Cleaner Solutions for Mixed Loads
Non-enzymatic solutions clean with detergents and alkaline salts rather than enzymes. General purpose listings name blood and saliva alongside pumice and polishing compounds, on instruments, burs, crowns, dentures and orthodontic appliances, which makes them the usual choice for laboratory items and mixed loads. Some are strongly alkaline and can etch aluminum, so aluminum items go into a solution whose label lists them.
A few concentrates are also registered with the EPA as disinfectants, but instruments that come out of such a bath are still sterilized afterward.
For mixed loads that include plastic and rubber items, prosthetics or scaler tips, a non-ammoniated general purpose concentrate in a metered-dose bottle keeps the dilution consistent.
Mixed metal, plastic and rubber loads: BioSonic UC30 General Purpose Super Concentrate
BioSonic UC30 is a non-ammoniated, non-ionic, phosphate-free ultrasonic cleaning solution that removes blood, saliva and microscopic particles from dental instruments, crowns, bridges, dentures and ultrasonic scaler tips. The MeterDose bottle dispenses exact amounts for a 1:64 dilution, and the solution is safe for all dental tools, including plastic and rubber. It can also be used as an instrument presoak. Best for: mixed loads with plastic and rubber items, prosthetics and scaler tips cleaned in the same unit, teams that want metered dosing.
Tablets, Packets and Metered Doses
Pre-measured formats fix the dose of ultrasonic cleaner solution: each tablet or single-dose packet makes one gallon, or two tablets make a gallon for some enzymatic brands, so nobody measures liquid at the sink. With a liquid concentrate, the dilution decides how long a bottle lasts: a gallon used at 1 oz per gallon fills a one-gallon tank 128 times, while a stronger mix at 1:10 fills it ten times.
For teams that prefer not to measure liquid concentrate, one effervescent tablet per gallon removes the measuring step.
Pre-measured doses: Cleanlets General Purpose Ultrasonic Cleaning Tablets
Cleanlets General Purpose tablets use an effervescent formula that dissolves fully in hot or cold water, and each tablet makes one gallon of ultrasonic cleaning solution. The solution removes common soils such as blood, tissue, plaster, pumice and buffing compounds without leaving residue on instruments or in the tank, and the tablets are individually blister-packed. Best for: tanks filled by the gallon, teams that prefer a fixed dose to measuring liquid, loads with clinical and laboratory soils.
Rust, Stains and Cement: Specialty Solutions and Protection
Tartar, stain and cement removers are stronger and narrower than general purpose solutions. Acid removers for calculus and stains on dentures, bridges and orthodontic appliances are used undiluted in a covered glass beaker placed inside the main bath for 5 to 10 minutes, and acrylic items are then neutralized in a baking soda solution.
On instruments, the aim is to keep stains and rust from forming: some solutions include agents against the minerals in tap water, and corrosion inhibitors, often called instrument milk, are applied as a short dip after cleaning and before sterilization.
For restorative instruments that come back with set cement or early staining, an enzymatic powder with a passivation process combines cleaning and surface protection.
Set cement and early staining: Brite Shield Instrument Cleaner and Protectant
Brite Shield is an enzymatic powder for static soak and ultrasonic cleaning of dental instruments, burs and impression trays. It removes bioburden along with set glass ionomer, carboxylate and zinc phosphate cements, alginate and stone, while a passivation process coats stainless steel instruments to restrict rust and corrosion and restore a lustrous finish. Best for: restorative instruments with set cement, burs and impression trays, stainless steel instruments that have started to stain.
How Often Should Ultrasonic Cleaner Solution Be Changed?
Ultrasonic cleaner solution is changed as often as its label and the unit's instructions specify, since CDC ties instrument reprocessing to the manufacturer's instructions and does not set an interval of its own. Bath life differs by product, up to 30 days once mixed for one enzymatic tablet. Monitor strips, run daily or with each load, carry a colored test soil: when the bath removes it completely, the unit and the solution are working.
After the bath, CDC recommends a water rinse to remove detergent residue, and instruments are dried and inspected before they go into sterilization pouches or cassettes. When cleaning cannot start right away, CDC suggests soaking instruments in a detergent or an enzymatic cleaner to keep soil from drying, and advises against glutaraldehyde and other high-level disinfectants as holding solutions.
Ultrasonic Cleaner Solutions and Alara: Get the Best Deals from Trusted Suppliers
Ultrasonic cleaner solution is used up with every tank fill, and the same concentrate or tablet is sold by many vendors at different prices. Alara compares real-time offers on the solutions described above, from Hu-Friedy Enzymax and Tri-Clean to BioSonic UC30, Cleanlets and Brite Shield, across 15+ verified vendors.
Compare ultrasonic cleaner solution prices across 15+ verified vendors.
Add the ultrasonic cleaning solutions and tablets your practice uses every day to your Alara cart and see exactly how much your practice saves today
References
- Seneviratne CJ, Khan SA, Zachar J, Yang Z, Kiran R, Walsh LJ. Efficacy of Ultrasonic Cleaning Products With Various Disinfection Chemistries on Dental Instruments Contaminated With Bioburden. Int Dent J. 2025;75(3):1632-1639. PMID: 40138997. DOI: 10.1016/j.identj.2025.02.009
- Cayo-Rojas CF, Brito-Avila E, Aliaga-Marinas AS, Hernandez-Caba KK, Saenz-Cazorla ED, Ladera-Castaneda MI, Cervantes-Ganoza LA. Cleaning of endodontic files with and without enzymatic detergent by means of the manual method versus the ultrasonic method: An experimental study. J Int Soc Prev Community Dent. 2021;11(3):307-315. PMID: 34268193. DOI: 10.4103/jispcd.JISPCD_8_21
More Articles

Rotary Endodontic Files Compared: Motion, Taper and Heat-Treated NiTi
Rotary endodontic files compared by motion, taper and NiTi heat treatment, from ProTaper Gold and HyFlex EDM to WaveOne Gold, ZenFlex and TF Adaptive.
November 18, 2026

Best Prophy Paste for Dental Hygiene Appointments: Grit, Fluoride and Format
Prophy paste by grit, RDA, fluoride and format: selective polishing, heavy stain, sensitive teeth, restorations, gluten-free pastes, cups and jars.
November 16, 2026

Articulating Paper Guide: Thickness, Paper vs Film, Colors and Holders
Articulating paper from 200 microns to 8-micron foil: paper vs film, two-color marking, strips vs horseshoe, forceps and what the marks can show.
November 12, 2026